  1. GEOS-8018

WMS cascading fails with NPE when advanced projection handling gets disabled

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Medium
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 2.10.3, 2.11-RC1
    • Component/s: WMS
    • Labels:
      None

      Description

      This is a consequence of two elements:

      • WMS reader returning a null format
      • A change added to handle band selection optimization that assumes that is never null instead, which triggers only in the non APH case

        Attachments